Ansi A117 1 2012 Accessibility Standards



ASTM c90

ASTM c90

...date. 1. Scope 1.1 This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: (1) normal weight, (2) medium weight, and (3)...

ASTM a126

ASTM a126

...not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers three classes of gray iron for castings intended for use as valve pressure retaining parts, pipe fittings, and flanges....

ASTM c270

ASTM c270

...does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers mortars for use in the construction of non-reinforced and reinforced unit masonry structures. Four types of mortar are...

ASTM d 698

ASTM d 698

...compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors. 1. Scope 1.1 These test methods cover laboratory compaction methods used to determine the relationship between molding water content and dry...

ASTM a148

ASTM a148

...not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date....

ASTM a 276

ASTM a 276

...and users of cemented carbides.   1. Scope 1.1 This test method specifies procedures for the metallographic determination of apparent porosity in cemented carbides. Note 1—The term “apparent porosity” is construed to mean all microstructures observed on a properly prepared, unetched surface, including structures resulting from uncombined carbon, non-metallic...

ASTM d3039

ASTM d3039

...volume percent reinforcement. Properties, in the test direction, which may be obtained from this test method include the following:   Ultimate tensile strength, Ultimate tensile strain, Tensile chord modulus of elasticity, Poisson’s ratio, and Transition strain. 1. Scope 1.1 This test method determines the in-plane tensile properties of polymer...

ASTM d2321

ASTM d2321

...given in Appendix X2.   1. Scope 1.1 This practice provides recommendations for the installation of buried thermoplastic pipe used in sewers and other gravity-flow applications. These recommendations are intended to ensure a stable underground environment for thermoplastic pipe under a wide range of service conditions. However, because of...

ASTM f88

ASTM f88

...of fixtures and techniques are illustrated in Fig. 1. Technique A: Unsupported—Each tail of the specimen is secured in opposing grips and the seal remains unsupported while the test is being conducted. Technique B: Supported 90° (By Hand)—Each tail of the specimen is secured in opposing grips and the...

ASTM e399

ASTM e399

...to the expected loading and environment, and in relation to the sensitivity and reliability of the crack detection procedures that are to be applied prior to service and subsequently during the anticipated life. 1. Scope 1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials...

ICC A117.1-2017 Accessible and Usable Buildings and Facilities

ISBN: 978-1-60983-701-3 Publisher: ICC Pages: 200; For new buildings and additions, enhanced dimensions for the clear floor space, turning space and the accessible route.

ICC A117.1-2009 Standard and Commentary: Accessible and ...

Store > ICC A117.1-2009 Standard and Commentary: Accessible and Usable Buildings and Facilities

The ADA, ICC/ANSI A117.1 and Kitchen Sinks in Break Rooms ...

Mark brings up an excellent point in that there are always exceptions and various levels of regulation in effect. The 2010 ADA Standards for Accessible Design as put ...

ANSI/ASHRAE/IES Standard 90.1-2013 Energy Standard for ...

ANSI/ASHRAE/IES Standard 90.1-2013 Energy Standard for Buildings Except Low-Rise Residential Buildings - (I-P Edition)

Free PDFs - International Building Code, ADA and More!

Free! and all in one place; a list of PDFs for popular building codes & accessibility standards; 2015 IBC, 2013 CBC, NFPA 101, ADA, FHA, ANSI A117.1 & more!

New Hampshire Accessibility Code Requirements - NH.gov

New Hampshire Accessibility Code Requirements Approved by the NH Committee on Architectural Barrier-Free Design on January 17, 2012 This document is to be used as a ...

UFAS - United States Access Board

* 2 percent of total. ** 20 plus 1 for each 100 over 1000. EXCEPTION: The total number of accessible parking spaces may be distributed among parking lots, if greater ...

Home - United States Access Board

An independent federal agency devoted to accessibility for people with disabilities. Accessibility guidelines and standards, technical assistance, training, research ...

C ANSI 504.5 2” Marking on Stair Treads - NCDOI

2 2BEnhanced Reach Ranges: 6 or More 3BWhen Submitting Alteration Plans The 2004 NC Accessibility Code was very clear about what to do when a building

DHS: Codes, Standards and other Rules - IN.gov

675 IAC 13-1: Fire and Building Safety Standards (See NFPA list below) 675 IAC 13-2.3: Indiana Building Code, 1998 Edition (1997 UBC, Vol. 1, 2 and 3) CABO/ANSI A117 ...