ASTM E2112 STANDARD PRACTICE FOR INSTALLATION OF EXTERIOR WINDOWS, DOORS AND SKYLIGHTS
Revision/ Edition: 07 Chg: Date: 02/01/07
ASTM E2112 pdf

Document Abstract

This ASTM E2112 practice covers the installation of fenestration products in new and existing construction. ASTM E2112, For the purpose of this practice, fenestration products shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, as used primarily in residential and light commercial buildings.

This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roof construction, sheet metal work, and joint sealant practices.

This ASTM E2112 practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems and Membrane/Drainage Systems, in order to ensure the continuity of the building envelope. This practice attempts to educate the installer, builder, architect, and other users in the identification and understanding of the water shedding system of the building envelope.

This practice covers the installation process from preinstallation procedures through post-installation procedures, for single units or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whether such fabrication takes place in a factory or at the intended installation site. ASTM E2112, The installer should check with the manufacturer of factory-assembled units for instructions for anchoring. ASTM E2112, When using field-mulled units, follow manufacturer’s recommendations and make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration products for a given application, nor the selection of other products or systems for use in the installation.

This practice provides minimum requirements that will help to accomplish the installation of fenestration products in an effective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may be required. ASTM E2112, In the event that the manufacturer’s installation instructions provided with the product conflict with requirements of this practice, the manufacturer’s instructions shall prevail. ASTM E2112, This practice is not intended to limit or exclude other new procedures that may refine or further improve the effectiveness of fenestration installation.

This practice is intended to be used for background information in order to develop training manuals and training programs. ASTM E2112, Further, this practice attempts to consolidate and unify the various steps of construction, tying together the various trades involved with the continuity between fenestration products and the building envelope.

The text of this practice references notes and footnotes that provide explanatory material. ASTM E2112, These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this practice.

The values stated in inch-pound units are to be regarded as the standard. The values shown in parentheses are for information only.

This standard has not been created to address all issues related to every possible installation situation one might experience in the field. ASTM E2112, Furthermore, this practice does not purport to provide fail-safe installation methods, assurance or protection against installation deficiencies, or a standard by which architects can specify or ensure delivered performance.

NOTE 1—There are no ISO standards covering the primary subject matter of this practice.

This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 5, Related Procedures. Where a lead hazard is known or suspected, refer to ASTM Standards on Lead Hazards Associated with Buildings and to applicable state and federal regulations. Where an asbestos hazard is known or suspected, refer to the ASTM Manual on Asbestos Control, and to applicable state and federal regulations, ASTM E2112.